This module provides convenience conversions often used in survey workflows. The conversions are intended as practical calculator functions.
These are the explicit formulas used by the app7s conversion helpers. Any CTL/VCF behaviour is described at a high level only.
dens15air = dens15vac * 1.000149926 - 1.199407795
dens15vac = (dens15air + 1.199407795) / 1.000149926
relDens15 = dens15vac / 999.102
relDens60 = 141.5 / (api + 131.5)
dens15air = dens15vacTo15Air(dens15vac)
kgToLongTons = 0.0009842065276
longTons = cbmAt15 * dens15air * kgToLongTons
vcf = CTL_or_VCF(dens15vac, baseTemp=15.5556 C, group)
barrels = cbmAt15 / (vcf * 0.1589872949)